APK-60 High-Speed Automatic Effervescent Tablets Tube Filling Machine

50 to 60 tubes a minute, with automatic rejection of short-count tubes

Speed is the obvious difference — 50 to 60 tubes a minute against 40. The less obvious one matters more: this machine detects a tube that’s a tablet short and rejects it, rather than capping it and sending it down the line.

1. Speed: 50 to 60 tubes a minute

2. Short-count rejection: a tube missing a tablet is diverted, not capped

3. Tablets: Ø25 mm, up to 6 mm thick, 10 to 20 per tube

4. Power: 2 kW, built to your U.S. supply at 60 Hz

5. Weight: 1,000 kg. Check your floor before you order

Is this the right machine for you?

✓ Yes, if…

✕ Buy something else if…

Short-Count Tubes Leave the Line

The 40-series locks out the cap when a tablet is missing, which leaves you an uncapped tube travelling down the line. This machine pushes it out into a separate chute. At 60 tubes a minute, that’s the difference between finding it now and finding it at the packing bench.

Cap Feed Sized for the Speed

A vibrating hopper orients caps and feeds them down the track continuously. On a 40-tube line the cap feed has slack; at 60 it doesn’t, which is why this machine’s sorter is scaled up rather than carried over.

50 to 60 Tubes a Minute

Fifty percent more than the 40-series, from the same screening-and-row logic running faster. The tablets are still laid flat and pushed in sideways — speed here comes from the indexing and the cap feed keeping up, not from handling the tablets any harder.

SUS316L Where the Tablets Touch

Effervescent tablets carry citric and malic acid, and they shed that acid as dust. Contact parts are SUS316L; the table canopy is SUS304.

Technical specification

Specification APK-60 What it means for you
Speed 50–60 tubes/min Depends on tablet size and stack count
Tablets per tube 10–20 Set at build; tell us your count
Tablet diameter 25 mm —
Tablet thickness Up to 6 mm Thickness variance must stay within ±0.2 mm
Tablet hardness Above 5 kg Softer tablets chip in the track
Tube inner diameter At least 2 mm larger than the tablet Below that it jams
Indexing Stepper motor and indexing disk —
Short-count tubes Pushed out into a separate chute The 40-series locks out the cap instead
Control Siemens PLC and touchscreen —
Power 2 kW, 60 Hz Built to your U.S. supply. We confirm the voltage with your quote
Compressed air 0.5–0.6 MPa, up to 0.24 m³/min —
Dust port 38 mm Extractor supplied by you
Dimensions 3,300 × 2,000 × 1,750 mm —
Weight 1,000 kg Check your floor before you order
Contact parts SUS316L Frame cover SUS304

Model comparison

Model Indexing Speed Power Weight
APK-40A Pneumatic 35–40 tubes/min 1.2 kW 420 kg
APK-40B Stepper + indexing disk 35–40 tubes/min 1.5 kW 420 kg
APK-60 Stepper, with short-count rejection 50–60 tubes/min 2 kW 1,000 kg
APKZL-60 Tube labeller 60 tubes/min 0.8 kW 320 kg

The 40A and 40B run at the same speed and weigh the same. What differs is how each station is stopped — and that shows up when your tablet thickness varies.

Production Applications

Vitamin C and immunity effervescents

The largest effervescent category. Ø25 mm tablets, 10 or 20 to a tube.

Electrolyte and hydration tablets

Thinner tablets in the same tube. Thickness consistency matters more than diameter here.

Magnesium and mineral effervescents

Larger, denser tablets. Check hardness — under 5 kg they chip in the track.

Long runs at volume

One tablet spec for weeks at 50 to 60 tubes a minute. At that rate, pushing out short-count tubes is what saves you from finding them at the packing bench.

What changing over involves

What changed

What you adjust

Roughly

Same tablet, different count per tube

Track setting

15–30 minutes

Different tube diameter

Tube guides and cap vibrating disk

15–30 minutes

Different tablet diameter

Row alignment rails and track guides

15–30 minutes

Tablet thickness drifts within ±0.2 mm

Nothing — but that’s the limit

—

Beyond ±0.2 mm of thickness variance, no adjustment fixes it, on this machine or any other.

What to check before you buy

01

Your tablet, before the machine

Hardness above 5 kg, thickness variance within ±0.2 mm, and a tube at least 2 mm wider inside than your tablet. Those three decide whether any tube filler runs cleanly on your product — ask any supplier to confirm them against your actual samples.

02

What happens to a short-count tube

Some machines lock out the cap. Others push the tube out of the line. Ask which, because one of them still leaves you a tube to find at the packing bench.

03

Installation and training

Ask what's included and what costs extra.

Why Choose AIPAK?

One Point of Contact

One project engineer handles your machine from proposal to commissioning, so you’re not chasing five suppliers for one answer.

We Run Your Tablets and Tubes Before You Order

Send us some tablets and empty tubes. We run them on the machine and send them back, so you can check the count and the tablet edges yourself. You decide whether to talk quotes after that.

A U.S. Number, Answered by Us

+1 (213) 526-8644, answered by our engineers 9 AM–7 PM China time, Monday to Friday. That’s evening and overnight in the U.S., so leave a message or send a WhatsApp anytime and we’ll pick it up first thing.

Spare Parts and Lead Time, in Writing

A kit of wear parts ships with your machine. Every part in the kit, and the lead time for anything outside it, is listed in your quote in writing.

Questions About the APK-60

How does the APK-60 handle fragile effervescent tablets without chipping their edges at 60 tubes a minute?

The machine is engineered around a horizontal vibratory sorting table and screening channels that arrange tablets into a single overlapping row. Tablets are systematically aligned flat before a gentle mechanical cylinder shuffles them into the tube mouth, entirely removing vertical drops and preserving raw tablet hardness.

What are the strict tablet hardness and thickness tolerance limits required to run smoothly on this model?

To ensure reliable row counting and jam-free insertion, your raw formulation must maintain a minimum hardness threshold of above 5kg. Additionally, to prevent count variations from cumulative stacking errors, tablet thickness variance must remain within a tight tolerance of ±0.2mm.

What happens if a tube suffers from an incomplete tablet count or a missing cap?

The line features a multi-point sensor verification array governed by the Siemens PLC. If a container displays an incorrect tablet count or experiences a capping failure, the system skips the sealing step to protect component integrity and automatically directs that specific uncapped tube into an integrated rejection chute.

How does the system manage dust accumulation during high-volume continuous manufacturing?

The sorting track drops fine powder away from the tablet path as it runs. The rest is taken away through a 38 mm port that connects to your own dust extractor. The extractor itself isn’t included.

Is it easy to adjust the machine rails when switching between completely different tube lengths?

Yes. Your operator adjusts or swaps the tube feed rails, the cap vibrating disk and the row channels. The changeover table above shows what each change involves.

Can this machine handle tubes if the inner diameter is nearly identical to the tablet width?

No. Your tube’s inner diameter has to be at least 2 mm larger than your tablet, or the tablets jam at the tube mouth.

Does it run on US power?

Yes. We build to your U.S. supply at 60 Hz and confirm the voltage with your quote.

How do spare parts work?

A kit of wear parts ships with your machine. Every part in the kit, and the lead time for anything outside it, is listed in your quote in writing.

Customers Also Interested In...

Send Us Tablets and Tubes

Three things decide whether any of these machines runs cleanly on your product, and speed isn’t one of them.

Your tablets need to be harder than 5 kg — softer than that and the edges chip in the track. Thickness has to stay inside ±0.2 mm, or the stack height drifts and the count goes wrong. And your tube’s inner diameter has to be at least 2 mm wider than your tablet, or it jams at the mouth.

Send us samples of both and we’ll check all three before we quote. If your tablet doesn’t clear one of them, we’d rather tell you now than after the machine ships.

  • Reply within one business day
  • Your tablets and tubes run on the machine before you order
  • Your formula and specs stay with us
Scroll to Top