APK-40B Automatic Effervescent Tablets Tube Filling Machine

Stepper indexing, 35 to 40 tubes a minute, 10 to 20 tablets per tube

Pneumatic stops drift as they wear, and that drift shows up as a tablet caught on the tube mouth. This machine indexes with a stepper motor and a mechanical dividing disk instead. Same speed and same footprint as the 40A — what you’re buying is position that holds as your tablet thickness varies.

1. Speed: 35 to 40 tubes a minute

2. Indexing: stepper motor with mechanical dividing disk

3. Tablets: Ø25 mm, up to 6 mm thick, 10 to 20 per tube

4. Power: 1.5 kW, built to your U.S. supply at 60 Hz

Is this the right machine for you?

✓ Yes, if…

✕ Buy something else if…

Stepper Indexing, Not Pneumatic Stops

Each station is positioned by a stepper motor turning a mechanical dividing disk. A pneumatic stop gets there by hitting a hard limit — reliable when everything is fresh, less so as the cylinder and the stop wear. A stepper goes to a number and stays there.

Screening Track Before the Tube

Tablets pass a screening section that drops out chips and broken pieces before they reach the row that goes into the tube. It also sets the two conditions your tablets have to meet: hardness above 5 kg, and thickness variation within ±0.2 mm. Outside those, no amount of indexing precision helps.

Siemens PLC and Touchscreen

Parameters are entered on screen and recalled, not set by feel. When you come back to a tablet you ran last month, you enter the same numbers rather than re-tuning the track.

No Tablet, No Tube, No Cap

Optical sensors check each station before it acts. If the count is short or a cap is missing, the capping cylinder is locked out for that tube. The tube leaves uncapped, so your operator can pull it at the exit. Automatic rejection is on the APK-60.

Tubes Fed in One Direction

A swinging bucket arranges tubes and feeds them onto the track all facing the same way. Long, light tubes tumble easily, so this is the station that decides whether the rest of the machine gets a steady supply.

Same Speed as the 40A. Different Reason to Buy It

Both machines run 35 to 40 tubes a minute, weigh 420 kg and take the same floor. What you’re paying the difference for is position that holds when your tablet thickness moves inside its ±0.2 mm window — and when you change products often enough that the track gets reset regularly.

Technical specification

Specification

APK-40B

What it means for you

Speed

35–40 tubes/min

Depends on tablet size and stack count

Tablets per tube

10–20

Set at build; tell us your count

Tablet diameter

25 mm

—

Tablet thickness

Up to 6 mm

Thickness variance must stay within ±0.2 mm

Tablet hardness

Above 5 kg

Softer tablets chip in the track

Tube inner diameter

At least 2 mm larger than the tablet

Below that it jams

Indexing

Stepper motor and indexing disk

The 40A uses pneumatic cylinders

Control

Siemens PLC and touchscreen

—

Power

1.5 kW, 60 Hz

Built to your U.S. supply. We confirm the voltage with your quote

Compressed air

0.5–0.6 MPa, up to 0.28 m³/min

—

Dust port

38 mm

Extractor supplied by you

Dimensions

1,600 × 1,500 × 1,600 mm

—

Weight

420 kg

—

Contact parts

SUS316L

Frame cover SUS304

 

Model comparison

Model

Indexing

Speed

Power

Weight

APK-40A

Pneumatic

35–40 tubes/min

1.2 kW

420 kg

APK-40B

Stepper + indexing disk

35–40 tubes/min

1.5 kW

420 kg

APK-60

Stepper, with short-count rejection

50–60 tubes/min

2 kW

1,000 kg

APKZL-60

Tube labeller

60 tubes/min

0.8 kW

320 kg

The 40A and 40B run at the same speed and weigh the same. What differs is how each station is stopped — and that shows up when your tablet thickness varies.

Production Applications

Vitamin C and immunity effervescents

The largest effervescent category. Ø25 mm tablets, 10 or 20 to a tube.

Electrolyte and hydration tablets

Thinner tablets in the same tube. Thickness consistency matters more than diameter here.

Magnesium and mineral effervescents

Larger, denser tablets. Check hardness — under 5 kg they chip in the track.

Multi-SKU production

Several tablet specs through one machine. Stepper indexing holds position as the thickness changes between products.

What changing over involves

What changed

What you adjust

Roughly

Same tablet, different count per tube

Track setting

15–30 minutes

Different tube diameter

Tube guides and cap vibrating disk

15–30 minutes

Different tablet diameter

Row alignment rails and track guides

15–30 minutes

Tablet thickness drifts within ±0.2 mm

Nothing — but that’s the limit

—

Beyond ±0.2 mm of thickness variance, no adjustment fixes it. That’s what separates the 40A from the 40B.

What to check before you buy

01

Your tablet, before the machine

Hardness above 5 kg, thickness variance within ±0.2 mm, and a tube at least 2 mm wider inside than your tablet. Those three decide whether any tube filler runs cleanly on your product — ask any supplier to confirm them against your actual samples.

02

What happens to a short-count tube

Some machines lock out the cap. Others push the tube out of the line. Ask which, because one of them still leaves you a tube to find at the packing bench.

03

Installation and training

Ask what's included and what costs extra.

Why Choose AIPAK?

One Point of Contact

One project engineer handles your machine from proposal to commissioning, so you’re not chasing five suppliers for one answer.

We Run Your Tablets and Tubes Before You Order

Send us some tablets and empty tubes. We run them on the machine and send them back, so you can check the count and the tablet edges yourself. You decide whether to talk quotes after that.

A U.S. Number, Answered by Us

+1 (213) 526-8644, answered by our engineers 9 AM–7 PM China time, Monday to Friday. That’s evening and overnight in the U.S., so leave a message or send a WhatsApp anytime and we’ll pick it up first thing.

Spare Parts and Lead Time, in Writing

A kit of wear parts ships with your machine. Every part in the kit, and the lead time for anything outside it, is listed in your quote in writing.

Questions About the APK-40B

What does the APK-40B do better than the 40A?

It positions each station with a stepper motor and a mechanical indexing disk instead of pneumatic stops. A pneumatic stop drifts as the cylinder wears; a stepper goes to the same position every time. That matters when your tablet thickness varies, or when you change products often.

How does the APK-40B handle fragile effervescent tablets without chipping their edges?

The machine is engineered around a horizontal vibratory sorting table and screening channels that arrange tablets into a single overlapping row. Tablets are systematically aligned flat before a gentle mechanical cylinder shuffles them into the tube mouth, entirely removing vertical drops and preserving raw tablet hardness.

What are the strict tablet hardness and thickness tolerance limits required to run smoothly on this model?

To ensure reliable row counting and jam-free insertion, your raw formulation must maintain a minimum hardness threshold of above 5 kg. Additionally, to prevent count variations from cumulative stacking errors, tablet thickness variance must remain within a tight tolerance of ±0.2 mm.

What happens if a tube suffers from an incomplete tablet count or a missing cap?

The capping cylinder is locked out for that tube and the machine alarms. The tube leaves uncapped, so your operator can pull it at the exit. If you want short-count tubes pushed out of the line automatically, that’s the APK-60.

How does the system manage dust accumulation during high-volume continuous manufacturing?

The sorting track drops fine powder away from the tablet path as it runs. The rest is taken away through a 38 mm port that connects to your own dust extractor. The extractor itself isn’t included.

Is it easy to adjust the machine rails when switching between completely different tube lengths?

Yes. Your operator adjusts or swaps the tube feed rails, the cap vibrating disk and the row channels. The changeover table above shows what each change involves.

Can this machine handle tubes if the inner diameter is nearly identical to the tablet width?

No. Your tube’s inner diameter has to be at least 2 mm larger than your tablet, or the tablets jam at the tube mouth.

Does it run on US power?

Yes. We build to your U.S. supply at 60 Hz and confirm the voltage with your quote.

How do spare parts work?

A kit of wear parts ships with your machine. Every part in the kit, and the lead time for anything outside it, is listed in your quote in writing.

Customers Also Interested In...

Send Us Tablets and Tubes

Three things decide whether any of these machines runs cleanly on your product, and speed isn’t one of them.

Your tablets need to be harder than 5 kg — softer than that and the edges chip in the track. Thickness has to stay inside ±0.2 mm, or the stack height drifts and the count goes wrong. And your tube’s inner diameter has to be at least 2 mm wider than your tablet, or it jams at the mouth.

Send us samples of both and we’ll check all three before we quote. If your tablet doesn’t clear one of them, we’d rather tell you now than after the machine ships.

  • Reply within one business day
  • Your tablets and tubes run on the machine before you order
  • Your formula and specs stay with us
Scroll to Top