APC-12 Automatic Electronic Counting Machine
Twelve channels on the eight-channel footprint
The APC-12 counts at 20 to 40 bottles per minute across twelve channels. It’s the step up from eight — the same footprint, the same frame, more throughput.
1. ≥99.9% counting accuracy: Infrared sensor array with an algorithm that separates product from dust and overlapping units.
2. Dust compensation: The sensors compensate for airborne dust, so accuracy holds longer between cleanings on uncoated herbal tablets and other high-dust products.
3. Gentle feeding: Three-stage electromagnetic vibration separates delicate softgels and coated tablets without chipping them.
4. No bottle, no count: The gate stays closed until a bottle is in position, so product doesn’t spill between bottles.
Direct from our factory | Lead time confirmed in your quote | Installation and training available | Spare parts listed in your quote
Is the APC-12 the right size for you?
✓ This is a fit if…
- You need 20 to 40 bottles per minute
- You've outgrown an eight-channel machine but don't need sixteen
- You change over between products regularly
✕ Look elsewhere if…
- You need more than 40 bottles per minute → the APC-16 runs 20–80
- You run under 30 bottles per minute → the APC-8 costs less and does the job
- Your product is very dusty → the APC-16C
- You're counting gummies → send us a sample first
Technical specification
| Parameter | Value |
|---|---|
| Number of Channels | 12 |
| Counting Speed | 20–40 bottles/min |
| Applicable Products | Tablets, hard capsules, softgels |
| Tablet Size Range | Φ3–25 mm |
| Counting Accuracy | ≥ 99.9% |
| Control System | PLC & 10-inch color touchscreen |
| Construction Material | 316L stainless steel contact parts, 304 frame |
| Fill range | 2–9999 pieces, adjustable |
| Power | 0.8 kW, 60 Hz, built to your U.S. supply (voltage confirmed in your quote) |
| Dimensions | 1360 × 1350 × 1650 mm |
| Weight | 320 kg (Type A) / 380 kg (Type B) |
Eight models. Which one is yours?
Model | Channels | Speed | Best for… |
|
APC-B8 | 8 | 10–30 btl/min | R&D, small batches and short commercial runs | |
APC-8 | 8 | 10–30 btl/min | Continuous production at the same speed | |
APC-12 | 12 | 20–40 btl/min | Growing manufacturers with frequent changeovers | You are here |
APC-16 | 16 | 20–80 btl/min | Standard commercial bottling lines | |
APC-16C | 16 | 40–100 btl/min | High-dust products — enclosed track and reject station | |
APC-24 | 24 | 20–90 btl/min | Large-batch continuous production | |
APC-32 | 32 | 40–120 btl/min | Multi-product facilities where changeover cleaning matters | |
APC-48 | 48 | 40–150 btl/min | Ultra-high-speed lines |
All eight count the same way — infrared sensing, three-stage vibration, ≥99.9% accuracy. What changes is throughput and, on the enclosed models, how well accuracy holds on dusty products.
Twelve channels, same footprint
Twelve channels on the same 1360 × 1350 mm frame as the APC-8. Four more channels take you to 20 to 40 bottles per minute without taking more floor space.
Three-stage vibration
Three vibration plates thin the product flow progressively instead of forcing it apart in one step. Sticky softgels and irregular tablets arrive at the sensors in a single layer — which is what stops two overlapping units being counted as one.
Dust compensation
Dust on the sensor window is what makes accuracy drift through a shift. The sensors compensate for airborne particles rather than reading them as product, so you clean less often on uncoated herbal tablets and other high-friction products.
Recipe storage
The touchscreen stores settings for over 100 products — vibration frequency, bottle height, counting speed. Switching from a 60-count multivitamin to a 120-count softgel is loading a saved recipe, not re-finding settings by trial. If you run a lot of SKUs, this is where your output actually comes from.
No bottle, no count
The gate stays closed until a bottle is in position under it. If a bottle is missing, or a jam is detected downstream, the machine holds rather than dropping product onto the conveyor. You clean up less, and the count doesn’t break on the bottles either side of the gap.
What people count on these machines
Channel count sets your speed. What you’re counting sets everything else — how the product separates, how much dust reaches the sensors, and how gently it has to land in the bottle.
Tablets and hard capsules
The everyday case, and the one that sets the baseline. Uncoated tablets and hard capsules separate cleanly and drop straight, so channel count is what decides your speed. If this is most of what you run, work backwards from your bottles per hour and pick on throughput alone.
Softgels and fish oil capsules
Softgels stick to each other and to the track. Three-stage vibration separates them progressively instead of forcing them apart, so the shell doesn’t scuff on the way through.
Coated tablets and multivitamins
Coating dust builds on the sensor window through a shift. That’s what makes accuracy drift between cleanings — not the sensor itself. Dust compensation is what keeps the count steady from the first bottle to the last.
Gummies
Gummies deform under their own weight and stick to whatever they touch. Send us a sample before you order — gummies are the one product where we’d rather test than assume.
What changing over involves
What you changed | What gets adjusted | Roughly how long |
Same product, different count per bottle | Enter the new count on the screen | Seconds |
Same product, different bottle size | Bottle height and guide width, by hand-wheel | 10-30 minutes |
Different product, same size range | Load the saved recipe; wipe down the track | 10-30 minutes |
New product, first run | Set parameters, save as a recipe | 10-30 minutes |
Full teardown for deep clean | Hopper, vibration plates and counting head come out by hand | 10-30 minutes |
No tools for the parts you touch daily. The hopper, vibration plates and counting head come out by hand. Bottle height and guide width are hand-wheels with scales, so a repeat setting is dialed rather than found.
Save every product as a recipe. With over 100 slots there’s no reason not to. The first run of an SKU takes setup time; every run after is loading a saved set.
Cleaning is the long part, not the mechanics. Between two products in the same family it’s a wipe-down. Between an uncoated herbal tablet and a clear softgel it’s a full teardown. Budget by what you’re switching between, not by an average.
Three things to check before you buy any tablet counter
Accuracy, verified on your product
A demo with someone else's tablets proves nothing. Ask any supplier to run your product and show you the count sheet — how many bottles, how many miscounts, over how long. We do that at factory acceptance testing before the machine ships.
The manual
Your operator sets bottle height, vibration frequency and count from the screen. They need an English manual with the settings procedure in it, not a translated parts list. Ask to see it before you order.
Installation and training
The machine runs out of the crate. Getting it counting reliably across all your products takes someone who's set one up before. Our engineers install it, dial in each of your products, and train your operators. This is a paid service, quoted in your proposal.
Why Choose AIPAK?
One Point of Contact
One project engineer handles your machine from proposal to commissioning, so you’re not chasing five suppliers for one answer.
We Run Your Product Before You Order
Send us a sample of your tablets, capsules or softgels and we’ll run it on the machine and send you the count results. You decide whether to talk quotes after that.
A U.S. Number, Answered by Us
+1 (213) 526-8644, answered by our engineers 9 AM–7 PM China time, Monday to Friday. That’s evening and overnight in the U.S., so leave a message or send a WhatsApp anytime and we’ll pick it up first thing.
Spare Parts and Lead Time, in Writing
A kit of wear parts ships with your machine. Every part in the kit, and the lead time for anything outside it, is listed in your quote in writing.
APC-12 Automatic Tablet Counting Machine FAQ
The counting accuracy is ≥99.9%. A figure on a spec sheet doesn’t prove it on your product, so we run your tablets, capsules or softgels at factory acceptance testing and give you the count sheet before the machine ships.
Yes. The sensors count each piece as it passes, so color, transparency and shape don’t change the count. Heart-shaped or triangular tablets count the same way as round ones, as long as they fall between Φ3 and 25 mm. Gummies are the exception: send us a sample first.
Dust on the sensor window is what makes accuracy drift through a shift. The sensors compensate for airborne particles rather than reading them as product, and the windows wipe clean by hand. For very dusty or coated products, look at the APC-16C, which has enclosed counting channels and an automatic reject.
It depends on what you’re switching between. Changing the count per bottle takes seconds. A new bottle size, a different product or a full teardown for deep cleaning is roughly 10 to 30 minutes. The hopper, vibration plates and counting head come off by hand, with no tools.
The gate stays closed until a bottle is in position under it. If a bottle is missing, or a jam is detected downstream, the machine holds rather than dropping product onto the conveyor.
Yes. It runs standalone or with our bottle unscramblers, desiccant inserters, cappers, induction sealers and labelers. If you need it to report into a plant monitoring system, tell us at the quotation stage and we’ll confirm what’s involved.
We build to your U.S. supply at 60 Hz and confirm the voltage with your quote.
A kit of wear parts ships with your machine. Every part in the kit, and the lead time for anything outside it, is listed in your quote in writing.
Yes. Our engineer can install the machine in your plant, set up each of your products and train your operators. This is a paid service, quoted in your proposal.
Yes. Our machines are certified and use certified electrical components. Because the exact scope depends on the model and electrical configuration you select, our factory confirms it in writing before production.
Customers Also Interested In...
Send us your product and your bottles per hour
We’ll come back with a model recommendation, a layout drawing and a price. If the APC-12 isn’t the right size for you, we’ll tell you which one is.
Send your bottle dimensions and we’ll draw the line layout for free — where the counter sits, and how much conveyor you need either side.