SEM-120-III (SERVO) Softgel Encapsulation Machine
Eight plungers, Φ150 × 120 die roll, full servo drive
You’ve outgrown a lab machine and a full 250 line is more than you need. This machine has the same servo architecture as our flagship — independent spindle drives, automatic die alignment, automatic filling volume adjustment — on a Φ150 × 120 die roll instead of a 250. Up to 115,200 capsules an hour at 3# oval.
1. Output: up to 115,200 capsules an hour at 3# oval
2. Filling accuracy: ±0.5% on oils, ±1.5% on suspensions
3. Servo architecture: independent spindle drives and automatic die alignment, the same as our 250 flagship
4. Power:10 kW, three-phase, 60 Hz, built to your U.S. supply
Is this the right machine for you?
✓ Yes, if…
- You need 30,000 to 115,000 capsules an hour
- You run several capsule shapes and want settings recalled rather than re-tuned
- You've outgrown a lab machine and a 250 line is more than you need
- You already have drying capacity for this output, or you're buying it with the machine
✕ Buy something else if…
- You need more than 115,000 an hour → the 250 series doubles the die roll length
- You run one shape and one recipe → the SEM-250-II is mechanical, higher output, and costs less than servo
- You're still developing the formula → the SEM-100II is the trial machine
Technical specification
| Feature | SEM-120-III (SERVO) |
| Die Roll Speed | 0 – 6 RPM (Servo Stepless Control) |
| Die Roll Size | Φ150 × 120 mm |
| Plunger Quantity | 10 – 12 Plungers (High Density) |
| Filling Accuracy | ±0.5% (oil) / ±1.5% (suspension) |
| Total Power | 12.0 kW |
| Dimensions | 2150 × 1100 × 1950 mm |
| Machine Weight | 1,200 kg |
| Power Supply | Three-phase, 60 Hz |
Model comparison
Capsule size | SEM-100II | SEM-120-III | SEM-250-II | SEM-250-IIIA |
3# oval | 30,240 | 115,200 | 172,800 | 259,200 |
6# oval | 24,000 | 68,400 | 127,680 | 191,520 |
8# oval | 22,800 | 63,000 | 120,960 | 181,400 |
10# oval | 17,280 | 51,000 | 106,080 | 159,120 |
14# oval | 15,360 | 48,000 | 92,160 | 138,240 |
20# oval | 10,800 | 34,800 | 69,600 | 104,400 |
8# oblong | 18,240 | 49,200 | 109,200 | 163,800 |
10# oblong | 15,120 | 45,600 | 82,080 | 123,120 |
16# oblong | 13,680 | 32,400 | 69,120 | 103,680 |
20# oblong | 8,160 | 30,600 | 57,120 | 85,680 |
5# round | 24,480 | 79,200 | 158,400 | 237,600 |
10# round | 20,160 | 63,000 | 122,400 | 183,600 |
40# round | 5,760 | 27,600 | 66,240 | 99,360 |
Output depends on capsule size more than on anything else. A 3# oval and a 40# round come off the same machine at roughly a four-to-one ratio. Tell us your size and shape and we’ll give you the number for your product, not the headline one.
Advanced Full Servo Drive Technology
The SEM-120-III is equipped with an integrated servo system that eliminates complex mechanical gearboxes. Every movement—from die roll rotation to injection pump timing—is digitally synchronized, resulting in significantly lower noise, low vibration and reduced maintenance.
Precision Filling with Automatic Alignment
Powered by a high-precision servo injection system, the machine achieves a loading tolerance of ±0.5% on oils and ±1.5% on suspensions. The digital interface allows for “micro-adjustment” of the injection timing during operation, so fill weight is corrected without stopping the machine.
Φ150 × 120 Die Roll
Featuring a larger die roll size compared to entry-level models, the SEM-120-III provides a higher density of mold pockets. This allows for a substantial increase in output (30,600 to 115,200 capsules an hour, depending on size) while maintaining consistent seam pressure.
Intelligent Cooling Drum System
Equipped with a high-capacity internal cooling system, the machine maintains a constant temperature for the gelatin ribbon. An optional automatic ribbon control system uses contact sensors and servo motors to hold the ribbon at the thickness you set, so thin spots don’t turn into leakers.
Digital Recipe Management & Remote Support
Settings for each product are stored on the touchscreen and recalled when you switch back. The mold still changes by hand; what you save is the recalibration afterwards.
Applications & Industries
Fish oil and omega-3
The single largest softgel category. Clean oils hold the tightest tolerance these machines offer.
Vitamin D, E and fat-soluble actives
Small fills in small shells. At 3# and 5# sizes the plunger stroke is short, which is where filling accuracy matters most.
CoQ10 and suspension fills
Suspensions behave differently from oils and hold a wider tolerance. A colloid mill upstream is usually part of the answer — tell us your particle size.
What changing over involves
Swapping the mold is physical work. Recalling the settings is not
What changed | What you adjust | Roughly |
Same shape, new batch | Nothing on the machine | — |
Different fill, same shape | Injection timing and wedge temperature | 15–30 minutes |
Different capsule shape | Die rolls and injection pump swap, then recalibrate | 15–30 minutes |
Gelatin → vegan shell | Not a changeover. That’s a build configuration | — |
On the servo models, once a product is dialed in, speed, temperature, injection timing and ribbon thickness are stored as a digital profile. The mold still has to be swapped by hand — what you save is the recalibration afterwards.
Custom die rolls for a new shape take 2 to 3 weeks to machine and test.
What to check before you buy
Filling accuracy, and on which fill
Oil and suspension don't hold the same tolerance — ours are ±0.5% and ±1.5%. Ask any supplier which number applies to your product, and ask how it's verified at the factory acceptance test. A single headline figure usually means nobody has asked.
The manual
A clear English manual gets your operator running in a week instead of a month. Ask to see a sample page before you order.
Installation and training
One engineer to your plant, about two weeks. Travel and on-site costs are quoted separately. Installation isn't free anywhere — it's either a line item or it's inside the machine price. We quote it as a line item so you can see it.
Why Choose AIPAK?
We Size the Whole Line, Not Just the Encapsulator
An encapsulator running at full speed produces more capsules than most buyers expect to dry. A Φ1000 tumbler line needs 16 to 18 sections to support 24-hour production, not the 10 that cover a single shift. We calculate your drying, gelatin melting and inspection capacity alongside the machine — before you order, not after.
Formulation Decides Configuration
Vegan shells need a different wedge, a different spreader box and a heated cooling drum. High-viscosity fills need a colloid mill upstream. Suspension products hold a different filling tolerance than oils. Tell us what you are encapsulating and we will specify around it, rather than sending a standard machine and hoping it fits.
A U.S. Number, Answered by Us
+1 (213) 526-8644, answered by our engineers 9 AM–7 PM China time, Monday to Friday. That’s evening and overnight in the U.S., so leave a message or send a WhatsApp anytime and we’ll pick it up first thing.
Spare Parts and Lead Time, in Writing
A kit of wear parts ships with your machine. Every part in the kit, and the lead time for anything outside it, is listed in your quote in writing.
SEM-120-III (SERVO) FAQ
Traditional mechanical machines rely on complex gears, chains, and cam systems, which are prone to wear, noise, and synchronization lag over time. The SEM-120-III (SERVO) utilizes independent digital motors for each core movement. This eliminates mechanical backlash, ensures near-silent operation, and keeps the synchronization from drifting as the machine wears.
The servo machines hold ±0.5% on clean oils and ±1.5% on suspensions. On an expensive oil, a tighter fill means you can set the target closer to the label claim instead of overfilling to stay safe. Tell us your fill weight and we’ll work out what that’s worth at your volume.
Yes, but it is a build configuration rather than a software setting. Plant-based shells need a different thermal profile, and the machine has to be equipped for it: a different wedge, a closed spreader box and a heated cooling drum. Tell us at the quotation stage if vegan production is part of your plan.
The SEM-120-III aligns the injection timing with the die rolls from the first rotation. The servo synchronization allows the injection timing to align with the die rolls from the very first rotation. Additionally, the micro-lubrication system ensures the gelatin ribbon is clean, meaning less cleaning time for the machine and higher yields of “ready-to-dry” capsules.
Switching between different capsule sizes (e.g., from 10 Oval to 20 Oblong) typically requires hours of mechanical calibration on older machines. With our Smart HMI, once a product is optimized, all parameters—speed, temperature, injection timing, and ribbon thickness—are saved as a digital profile. A changeover now only requires a physical mold swap; the technical settings are restored with one touch.
Maintenance is significantly reduced compared to mechanical models. There are no chains to tighten or complex gearboxes to lubricate. Primary maintenance involves standard cleaning of the GMP contact parts and routine inspection of the pneumatic seals. We provide a comprehensive preventive maintenance schedule and a “Fast-Response” spare parts kit with every machine to ensure zero unplanned downtime.
Yes. We build to your U.S. supply at 60 Hz and confirm the voltage with your quote.
A kit of wear parts ships with your machine. Every part in the kit, and the lead time for anything outside it, is listed in your quote in writing.
Customers Also Interested In...
Send Us Your Fill and Your Capsule Size
Tell us what you’re encapsulating, your shell type, your capsule size and shape, your target output, and whether you already have drying capacity. We’ll come back with the encapsulator, the drying and the gelatin melting sized to match.
- Direct from our factory
- Lead time confirmed in your quote
- Installation and training available
- Spare parts listed in your quote